Specialty Surface Cellware and Inserts
- (10)
- (1)
- (147)
- (3)
- (2)
- (3)
- (73)
- (5)
- (15)
- (22)
- (1)
- (26)
- (5)
- (1)
- (40)
- (49)
- (1)
- (3)
- (1)
- (42)
- (2)
- (4)
- (13)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (6)
- (8)
- (29)
- (1)
- (1)
- (16)
- (6)
- (1)
- (5)
- (5)
- (8)
- (10)
- (1)
- (3)
- (2)
- (9)
- (1)
- (1)
- (12)
- (3)
- (3)
- (3)
- (3)
- (1)
- (6)
- (20)
- (9)
- (6)
- (10)
- (6)
- (9)
- (1)
- (8)
- (6)
- (4)
- (2)
- (1)
- (2)
- (5)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (1)
- (2)
- (3)
- (11)
- (9)
- (2)
- (4)
- (4)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (4)
Filtered Search Results
Altenloh Brinck & Co US INC. DBA: SABEU 24 well insert 8.0um PET PK48 (cellQART)
These cellQART Cell Culture Inserts come with PET membranes in clear optics in 24-Well format. The Inserts are tissue culture treated, sterile and are compatible with most standard Cell Culture Plates. They are ideal for in-situ phase contrast microscopy.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Altenloh Brinck & Co US INC. DBA: SABEU 24 well insert 5.0um PET PK48 (cellQART)
These cellQART Cell Culture Inserts come with PET membranes in clear optics in 24-Well format. The Inserts are tissue culture treated, sterile and are compatible with most standard Cell Culture Plates.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Ibidi USA Culture-Insert 2 Well for Self-Insertion, 25 Culture-Inserts in 10 cm Transport Dish
The ibidi Culture-Insert family is developed for wound healing, co-cultivation, and migration assays of adherent cells. The Culture-Insert 2 Well consists of two wells, separated by a 500 µm wall. A proprietary biocompatible adhesive is applied to the underside of the Culture-Insert which allows it to adhere to any flat, clean, and dry surface. A cell suspension can be placed in the wells allowing the adherent cells to grow in the designated areas only. After cell cultivation, the Culture-Insert can be removed by using sterile tweezers. The removal creates a clean, cell-free, and well-defined 500 µm gap. Live-cell imaging can be used to analyze the gap closure. 25 Culture-Insert 2 Well in 10 cm transport dish, sterile, 25 inserts/box
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Netwell™ Tissue Processing Inserts, 24 mm 500 µm mesh, Sterile Sterile
A modular and disposable system which can be used for the handling and processing of tissue slices in immunocytochemical staining, in 3-dimensional tissue culture, and in explant tissue culture. Home made devices are no longer necessary. These tissue processing wells are ready to fill all of your needs with the added convenience of being able to process up to 12 tissue specimens at one time (with one unit). Polyester mesh bottom inserts, carrier kit, and white or black polystyrene reagent tray.
Size: 24 mm
Mesh: 500 µm
Sterile: Sterile
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Amsbio LLC Alvetex Scaffold 12 well insert × 96
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Alvetex Scaffold 12 well insert × 96
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 6, 0.4 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 0.4 µm
Porosity: <6.8 percent
Culture Area: 3.14 cm2
Working volume: 1.5 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 12, 3 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 3 µm
Porosity: <7.7 percent
Culture Area: 1.13 cm2
Working volume: 1.1 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 6, 8 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 8 µm
Porosity: <2.7 percent
Culture Area: 4.1 cm2
Working volume: 1.75 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts, Packed in 24 Well Plate, Hanging, PC, 8.0m, Sterile, 24/CS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts. Permeable Cell Culture Inserts mimic in vivo conditions. Membrane remains suspended above well bottom, allowing co-culture: grow one cell line inside insert, and another below in the well. Ideal for drug transfer assays, transport studies, migration assays, and cell-cell interaction studies. Inserts center in wells, preventing membrane from touch-ing sides and wicking between insert and side wall. 0.4um pore size is ideal for co-culture and drug transport studies. 3.0 and 8.0um pore size is ideal for angiogenesis and chemotaxis experiments. Non -Treated Plates sold separately; carrier plate is Tissue Culture Treated. Plate manufactured from high clarity virgin polysytrene with polycarbonate membrane insert. RNase/DNase free and non-pyrogenic. Every case is printed with the lot number for quality traceability. Packaged sterile with 12 Inserts/plate, 2 Plates/case, 24 Inserts/case.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts, Packed in 6 Well Plate, Hanging, PC, 8.0m, Sterile, 12/CS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts. Permeable Cell Culture Inserts mimic in vivo conditions. Membrane remains suspended above well bottom, allowing co-culture: grow one cell line inside insert, and another below in the well. Ideal for drug transfer assays, transport studies, migration assays, and cell-cell interaction studies. Inserts center in wells, preventing membrane from touch-ing sides and wicking between insert and side wall. 0.4um pore size is ideal for co-culture and drug transport studies. 3.0 and 8.0um pore size is ideal for angiogenesis and chemotaxis experiments. Non -Treated Plates sold separately; carrier plate is Tissue Culture Treated. Plate manufactured from high clarity virgin polysytrene with polycarbonate membrane insert. RNase/DNase free and non-pyrogenic. Every case is printed with the lot number for quality traceability. Packaged sterile with 6 Inserts/plate, 2 Plates/case, 12 Inserts/case.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts, Packed in 6 Well Plate, Hanging, PET, 0.4m, Sterile, 12/CS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
CELLTREAT Scientific Products Permeable Cell Culture Inserts. Permeable Cell Culture Inserts mimic in vivo conditions. Membrane remains suspended above well bottom, allowing co-culture: grow one cell line inside insert, and another below in the well. Ideal for drug transfer assays, transport studies, migration assays, and cell-cell interaction studies. Inserts center in wells, preventing membrane from touch-ing sides and wicking between insert and side wall. 0.4um pore size is ideal for co-culture and drug transport studies. 3.0 and 8.0um pore size is ideal for angiogenesis and chemotaxis experiments. Non -Treated Plates sold separately; carrier plate is Tissue Culture Treated. Plate manufactured from high clarity virgin polysytrene with polyethylene membrane insert. RNase/DNase free and non-pyrogenic. Every case is printed with the lot number for quality traceability. Packaged sterile with 6 Inserts/plate, 2 Plates/case, 12 Inserts/case.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 24, 3 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 3 µm
Porosity: <7.7 percent
Culture Area: 0.47 cm2
Working volume: 0.5 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 6, 8 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 8 µm
Porosity: <2.7 percent
Culture Area: 3.14 cm2
Working volume: 1.5 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 24, 0.4 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 0.4 µm
Porosity: <6.8 percent
Culture Area: 0.47 cm2
Working volume: 0.5 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences NUNC™ Polycarbonate Membrane for Multidish 6, 3 µm pores
Treated and tested for cell attachment. Easy cultivation of most cell types without matrix coating. Used in a varity of applications, including transport studies, toxicity tests, chemotaxis studies and electron microscopy. Non-toxic. Packed in sterile Nunclon™Δ treated multidishes. Packed in resealable bags. Non-pyrogenic. Tabs for better grip/handling.
Pore size: 3 µm
Porosity: <7.7 percent
Culture Area: 4.1 cm2
Working volume: 1.75 ml
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More